/ Lọc theo: 
Danh mục: Cụm Từ ×
3 Sản phẩm được tìm thấy
  • Lưới
  • Danh sách
Code: SC101-01
Description:
Lamp Error (Scanning) The white level peak did not reach the prescribed threshold when the white plate was scanned.
Causes:
• LED defective • IDB (LED driver) defective • SBU defective • IPU defective • Power/signal harness defective • Condensation in scanner unit • Mirrors or lenses dirty or positioned incorrectly • White plate dirty or installed incorrectly
Remedy:
1. Turn the power off/on. 2. Perform the following operations: • Reconnect the power/signal harness. • Reattach/clean the mirrors/lenses. • Reattach/clean the white plate. • Reattach/clean the scanner guide plate. 3. Replace the following parts: • Replace the LED board. • Replace the IDB board or SIO board. • Replace the SBU board. • Replace the IPU board. • Replace the power/signal harness.

Code: SC101-02
Description:
Lamp Error (LED illumination adjustment) LED error was detected.
Causes:
• LED defective • IDB (LED driver) defective • Power/signal harness defective
Remedy:
1. Turn the power off/on. 2. Perform the following operations: • Reconnect the power/signal harness. 3. Replace the following parts: • Replace the LED board. • Replace the IDB board or SIO board. • Replace the power/signal harness.

Code: SC102
Description:
LED Illumination Adjustment Error The white level peak reached the prescribed threshold when the white plate was scanned after a specified number of adjustments.
Causes:
• LED defective • IDB (LED driver) defective • SBU defective • IPU defective • Power/signal harness defective
Remedy:
1. Turn the power off/on. 2. Reconnect the power/signal harness. 3. Replace the following parts: • Replace the LED board. • Replace the SBU board. • Replace the IDB board or SIO board. • Replace the IPU board. • Replace the power/signal harness.

Code: SC120
Description:
Scanner Home Position Error 1 The scanner home position sensor does not go OFF. Details: Error detection timing • During homing (when the machine is turned ON or when it returns from energy save mode) • During an automatic adjustment (when the machine is turned ON or when it returns from energy save mode) • During a scan from the ADF or exposure glass.
Causes:
• Scanner motor driver defective • Scanner motor defective • Scanner HP sensor defective • Harness defective • Timing belt, pulley, wire, or carriage not installed correctly
Remedy:
Replace the following parts: • Replace the HP sensor • Replace the scanner motor • Replace the harness.

Code: SC121
Description:
Scanner Home Position Error 2 The scanner home position sensor does not go ON. Details: Error detection timing • During homing • During an automatic adjustment • During a scan from the ADF or exposure glass.
Causes:
• Scanner motor driver defective • Scanner motor defective • Scanner HP sensor defective • Harness defective • Timing belt, pulley, wire, or carriage not installed correctly
Remedy:
Replace the following parts: • Replace the home position sensor • Replace the scanner motor • Replace the harness.
Code: SC141
Description:
Black level detection error The black level cannot be adjusted within the target during auto gain control.
Causes:
• SBU defective • IPU defective • Power/signal harness defective
Remedy:
1. Turn the power off/on. 2. Reconnect the power/signal harness. 3. Replace the following parts: • Replace the SBU board. • Replace the IPU board. • Replace the power/signal harness.

Code: SC142
Description:
White level detection error The white level cannot be adjusted to the second target level within the target during auto gain control.
Causes:
• SBU defective • LED defective • IDB (LED driver) defective • IPU defective • Power/signal harness defective • Scanner drive error • Condensation in scanner unit • Mirrors or lenses dirty or positioned incorrectly • White plate dirty or installed incorrectly
Remedy:
1. Turn the power off/on. 2. Perform the following operations: • Reconnect the power/signal harness. • Reattach/clean the mirrors/lenses. • Reattach/clean the white plate. 3. Replace the following parts: • Replace the SBU board. • Replace the LED board. • Replace the IDB board. • Replace the IPU board. • Replace the SIO board. • Replace the power/signal harness.

Code: SC144
Description:
SBU Communication Error • Connection to SBU cannot be confirmed. (Connection detection error) • Cannot communicate with the SBU, or the communication result is abnormal.
Causes:
• SBU defective • The other side of the communication (BCU, IPU etc.) defective • Power/signal harness defective
Remedy:
1. Turn the power off/on. 2. Reconnect the power/signal harness. 3. Replace the following parts: • Replace the SBU board. • Replace the IPU board. • Replace the BCU board. • Replace the power/signal harness.

Code: SC161-01
Description:IPU Error (LSYNC abnormal) An error occurred during the self-diagnostic test performed every time the machine is turned on, or returns to full operation from energy save mode.
Causes:• IPU (or BCU) board defective (ASIC-BREIT connection failure, LSYNC abnormal, etc.) • Cable between SBU and IPU (or BCU) defective
Remedy:• Replace the IPU (or BCU) board. • Check the cable between SBU and IPU (or BCU)
Code: SC165
Description:Copy data security unit error
Causes:• The copy data security option is enabled in the User Tools but the option board is detected as missing or defective. • The copy data security option was detected as defective when the machine was turned on or returned from energy save mode. • Copy data security unit board not installed correctly • Copy data security unit board defective
Remedy:• Reinstall the copy data security unit board. • Replace the copy data security unit board.

Code: SC185-00
Description:CIS Transmission Error The data read from the ASIC register on the CIS were not as expected. Details: • Occurs when a serial communication error between the CIS board and the DF board is detected. Occurs also when an error is detected during initialization of the ASIC on the CIS. • This can happen during initialization and feeding. The first and second consecutive occurrences of each constitute jams. The third occurrence constitutes an SC.
Causes:• Connector or harness between DF board and CIS board is disconnected or defective • ASIC on the CIS is defective • Boot failure of ASIC on the CIS
Remedy:• Reconnect the power/signal harness. • Replace the CIS unit (CIS and CIPB). • Replace the ADF control board. • Replace the power/signal harness.

Code: SC186-00
Description:CIS LED Error During initialization: • The ratio between the average values of leading-edge area and rear-edge area is out of specification. • Shading data peak value is below specification. During scanning: • Shading data peak value is below specification. Details: During initialization: • Occurs when one out of two CIS LEDs is malfunctioning, causing the difference between the average values of leading-edge area and rear-edge area to be large (CIS LED error detection). • Occurs when both of the CIS LEDs are malfunctioning (unlit), causing the shading data peak value to be extremely low (CIS white level adjustment). During scanning: • Occurs when both of the CIS LEDs are malfunctioning (unlit), causing the shading data peak value to be extremely low (CIS scan control, gray balance adjustment / confirmation). • The first and second consecutive occurrences of each constitute initial/feed jams. The third occurrence constitutes an SC.
Causes:During initialization: • One or two out of two CIS LEDs are defective During scanning: • Both of the CIS LEDs are defective.
Remedy:• Reconnect the power/signal harness. • Replace the CIS unit (CIS and CIPB). • Replace the CIS background white roller. • Replace the power/signal harness. • Replace the ADF main control board.